using System;
|
|
using System.Runtime.InteropServices;
|
|
|
|
namespace Vanara.PInvoke.VssApi
|
|
{
|
|
/// <summary>
|
|
/// <para>
|
|
/// [Beginning with Windows 8 and Windows Server 2012, the Virtual Disk Service COM interface is superseded by the Windows Storage
|
|
/// Management API.]
|
|
/// </para>
|
|
/// <para>Defines the set of the valid address types of a physical interconnect.</para>
|
|
/// </summary>
|
|
/// <remarks>
|
|
/// <para>
|
|
/// The VDS_INTERCONNECT structure includes a <c>VDS_INTERCONNECT_ADDRESS_TYPE</c> value as a member to indicate an interconnect address type.
|
|
/// </para>
|
|
/// <para>
|
|
/// <c>Note</c> Additional constants might be added to the <c>VDS_INTERCONNECT_ADDRESS_TYPE</c> enumeration in future Windows versions.
|
|
/// For this reason, your application must be designed to gracefully handle an unrecognized <c>VDS_INTERCONNECT_ADDRESS_TYPE</c>
|
|
/// enumeration constant.
|
|
/// </para>
|
|
/// </remarks>
|
|
// https://docs.microsoft.com/en-us/windows/win32/api/vdslun/ne-vdslun-vds_interconnect_address_type typedef enum
|
|
// _VDS_INTERCONNECT_ADDRESS_TYPE { VDS_IA_UNKNOWN, VDS_IA_FCFS, VDS_IA_FCPH, VDS_IA_FCPH3, VDS_IA_MAC, VDS_IA_SCSI } VDS_INTERCONNECT_ADDRESS_TYPE;
|
|
[PInvokeData("vdslun.h", MSDNShortId = "NE:vdslun._VDS_INTERCONNECT_ADDRESS_TYPE")]
|
|
public enum VDS_INTERCONNECT_ADDRESS_TYPE
|
|
{
|
|
/// <summary>This value is reserved.</summary>
|
|
VDS_IA_UNKNOWN = 0,
|
|
|
|
/// <summary>The address type is FCFS.</summary>
|
|
VDS_IA_FCFS,
|
|
|
|
/// <summary>The address type is FCPH.</summary>
|
|
VDS_IA_FCPH,
|
|
|
|
/// <summary>The address type is FCPH3.</summary>
|
|
VDS_IA_FCPH3,
|
|
|
|
/// <summary>The address type is MAC.</summary>
|
|
VDS_IA_MAC,
|
|
|
|
/// <summary>The address type is SCSI.</summary>
|
|
VDS_IA_SCSI,
|
|
}
|
|
|
|
/// <summary>
|
|
/// <para>
|
|
/// [Beginning with Windows 8 and Windows Server 2012, the Virtual Disk Service COM interface is superseded by the Windows Storage
|
|
/// Management API.]
|
|
/// </para>
|
|
/// <para>Defines the set of valid bus types of a storage device.</para>
|
|
/// </summary>
|
|
/// <remarks>
|
|
/// <para>
|
|
/// The VDS_LUN_INFORMATION, VDS_DISK_PROP, VDS_DISK_PROP2, and VDS_DRIVE_PROP2 structures include a <c>VDS_STORAGE_BUS_TYPE</c> value
|
|
/// as a member to specify the bus type of a LUN, disk, or drive.
|
|
/// </para>
|
|
/// <para>
|
|
/// <c>Note</c> The type specified in these structures matches the type that the driver or drivers reported and may not exactly match
|
|
/// the hardware.
|
|
/// </para>
|
|
/// <para>
|
|
/// <c>Note</c> Additional constants might be added to the <c>VDS_STORAGE_BUS_TYPE</c> enumeration in future Windows versions. For this
|
|
/// reason, your application must be designed to gracefully handle an unrecognized <c>VDS_STORAGE_BUS_TYPE</c> enumeration constant.
|
|
/// </para>
|
|
/// </remarks>
|
|
// https://docs.microsoft.com/en-us/windows/win32/api/vdslun/ne-vdslun-vds_storage_bus_type typedef enum _VDS_STORAGE_BUS_TYPE {
|
|
// VDSBusTypeUnknown, VDSBusTypeScsi, VDSBusTypeAtapi, VDSBusTypeAta, VDSBusType1394, VDSBusTypeSsa, VDSBusTypeFibre, VDSBusTypeUsb,
|
|
// VDSBusTypeRAID, VDSBusTypeiScsi, VDSBusTypeSas, VDSBusTypeSata, VDSBusTypeSd, VDSBusTypeMmc, VDSBusTypeMax, VDSBusTypeVirtual,
|
|
// VDSBusTypeFileBackedVirtual, VDSBusTypeSpaces, VDSBusTypeNVMe, VDSBusTypeScm, VDSBusTypeUfs, VDSBusTypeMaxReserved } VDS_STORAGE_BUS_TYPE;
|
|
[PInvokeData("vdslun.h", MSDNShortId = "NE:vdslun._VDS_STORAGE_BUS_TYPE")]
|
|
public enum VDS_STORAGE_BUS_TYPE
|
|
{
|
|
/// <summary>This value is reserved.</summary>
|
|
VDSBusTypeUnknown = 0,
|
|
|
|
/// <summary>The storage bus type is SCSI.</summary>
|
|
VDSBusTypeScsi,
|
|
|
|
/// <summary>The storage bus type is ATAPI.</summary>
|
|
VDSBusTypeAtapi,
|
|
|
|
/// <summary>The storage bus type is ATA.</summary>
|
|
VDSBusTypeAta,
|
|
|
|
/// <summary>The storage bus type is IEEE 1394.</summary>
|
|
VDSBusType1394,
|
|
|
|
/// <summary>The storage bus type is SSA.</summary>
|
|
VDSBusTypeSsa,
|
|
|
|
/// <summary>The storage bus type is Fibre Channel.</summary>
|
|
VDSBusTypeFibre,
|
|
|
|
/// <summary>The storage bus type is USB.</summary>
|
|
VDSBusTypeUsb,
|
|
|
|
/// <summary>The storage bus type is RAID.</summary>
|
|
VDSBusTypeRAID,
|
|
|
|
/// <summary>The storage bus type is iSCSI.</summary>
|
|
VDSBusTypeiScsi,
|
|
|
|
/// <summary>The storage bus type is Serial Attached SCSI (SAS).</summary>
|
|
VDSBusTypeSas,
|
|
|
|
/// <summary>The storage bus type is SATA.</summary>
|
|
VDSBusTypeSata,
|
|
|
|
/// <summary>
|
|
/// <para>The storage bus type is Secure Digital (SD).</para>
|
|
/// <para>Windows Server 2008, Windows Vista and Windows Server 2003:</para>
|
|
/// <para>Not supported.</para>
|
|
/// </summary>
|
|
VDSBusTypeSd,
|
|
|
|
/// <summary>
|
|
/// <para>The storage bus type is MultiMedia Card (MMC).</para>
|
|
/// <para>Windows Server 2008, Windows Vista and Windows Server 2003:</para>
|
|
/// <para>Not supported.</para>
|
|
/// </summary>
|
|
VDSBusTypeMmc,
|
|
|
|
/// <summary>
|
|
/// <para>This value is reserved for system use.</para>
|
|
/// <para>Windows Server 2008, Windows Vista and Windows Server 2003:</para>
|
|
/// <para>Not supported.</para>
|
|
/// </summary>
|
|
VDSBusTypeMax,
|
|
|
|
/// <summary/>
|
|
VDSBusTypeVirtual = 0xe,
|
|
|
|
/// <summary>
|
|
/// <para>The storage bus type is file-backed virtual.</para>
|
|
/// <para>Windows Server 2008, Windows Vista and Windows Server 2003:</para>
|
|
/// <para>Not supported.</para>
|
|
/// </summary>
|
|
VDSBusTypeFileBackedVirtual,
|
|
|
|
/// <summary/>
|
|
VDSBusTypeSpaces,
|
|
|
|
/// <summary/>
|
|
VDSBusTypeNVMe,
|
|
|
|
/// <summary/>
|
|
VDSBusTypeScm,
|
|
|
|
/// <summary/>
|
|
VDSBusTypeUfs,
|
|
|
|
/// <summary>The maximum value of the storage bus type range.</summary>
|
|
VDSBusTypeMaxReserved = 0x7f,
|
|
}
|
|
|
|
/// <summary>
|
|
/// <para>
|
|
/// [Beginning with Windows 8 and Windows Server 2012, the Virtual Disk Service COM interface is superseded by the Windows Storage
|
|
/// Management API.]
|
|
/// </para>
|
|
/// <para>Defines the set of the valid code sets (encodings) of a storage identifier.</para>
|
|
/// </summary>
|
|
/// <remarks>
|
|
/// <para>
|
|
/// The VDS_STORAGE_IDENTIFIER structure includes a <c>VDS_STORAGE_IDENTIFIER_CODE_SET</c> value as a member to indicate the code set of
|
|
/// a storage identifier.
|
|
/// </para>
|
|
/// <para>
|
|
/// <c>Note</c> Additional constants might be added to the <c>VDS_STORAGE_IDENTIFIER_CODE_SET</c> enumeration in future Windows
|
|
/// versions. For this reason, your application must be designed to gracefully handle an unrecognized
|
|
/// <c>VDS_STORAGE_IDENTIFIER_CODE_SET</c> enumeration constant.
|
|
/// </para>
|
|
/// </remarks>
|
|
// https://docs.microsoft.com/en-us/windows/win32/api/vdslun/ne-vdslun-vds_storage_identifier_code_set typedef enum
|
|
// _VDS_STORAGE_IDENTIFIER_CODE_SET { VDSStorageIdCodeSetReserved, VDSStorageIdCodeSetBinary, VDSStorageIdCodeSetAscii,
|
|
// VDSStorageIdCodeSetUtf8 } VDS_STORAGE_IDENTIFIER_CODE_SET;
|
|
[PInvokeData("vdslun.h", MSDNShortId = "NE:vdslun._VDS_STORAGE_IDENTIFIER_CODE_SET")]
|
|
public enum VDS_STORAGE_IDENTIFIER_CODE_SET
|
|
{
|
|
/// <summary>This value is reserved.</summary>
|
|
VDSStorageIdCodeSetReserved = 0,
|
|
|
|
/// <summary>The storage identifier is encoded as binary data.</summary>
|
|
VDSStorageIdCodeSetBinary,
|
|
|
|
/// <summary>The storage identifier is encoded as ASCII data.</summary>
|
|
VDSStorageIdCodeSetAscii,
|
|
|
|
/// <summary>
|
|
/// <para>The storage identifier is encoded as UTF-8.</para>
|
|
/// <para>Windows Vista and Windows Server 2003:</para>
|
|
/// <para>Not supported before Windows Vista with SP1 and Windows Server 2008.</para>
|
|
/// </summary>
|
|
VDSStorageIdCodeSetUtf8,
|
|
}
|
|
|
|
/// <summary>
|
|
/// <para>
|
|
/// [Beginning with Windows 8 and Windows Server 2012, the Virtual Disk Service COM interface is superseded by the Windows Storage
|
|
/// Management API.]
|
|
/// </para>
|
|
/// <para>Defines the set of valid types for a storage identifier.</para>
|
|
/// </summary>
|
|
/// <remarks>
|
|
/// <para>
|
|
/// The VDS_STORAGE_IDENTIFIER structure includes a <c>VDS_STORAGE_IDENTIFIER_TYPE</c> value as a member to indicate the storage
|
|
/// identifier type.
|
|
/// </para>
|
|
/// <para>
|
|
/// <c>Note</c> Additional constants might be added to the <c>VDS_STORAGE_IDENTIFIER_TYPE</c> enumeration in future Windows versions.
|
|
/// For this reason, your application must be designed to gracefully handle an unrecognized <c>VDS_STORAGE_IDENTIFIER_TYPE</c>
|
|
/// enumeration constant.
|
|
/// </para>
|
|
/// </remarks>
|
|
// https://docs.microsoft.com/en-us/windows/win32/api/vdslun/ne-vdslun-vds_storage_identifier_type typedef enum
|
|
// _VDS_STORAGE_IDENTIFIER_TYPE { VDSStorageIdTypeVendorSpecific, VDSStorageIdTypeVendorId, VDSStorageIdTypeEUI64,
|
|
// VDSStorageIdTypeFCPHName, VDSStorageIdTypePortRelative, VDSStorageIdTypeTargetPortGroup, VDSStorageIdTypeLogicalUnitGroup,
|
|
// VDSStorageIdTypeMD5LogicalUnitIdentifier, VDSStorageIdTypeScsiNameString } VDS_STORAGE_IDENTIFIER_TYPE;
|
|
[PInvokeData("vdslun.h", MSDNShortId = "NE:vdslun._VDS_STORAGE_IDENTIFIER_TYPE")]
|
|
public enum VDS_STORAGE_IDENTIFIER_TYPE
|
|
{
|
|
/// <summary>The storage identifier type is vendor specific.</summary>
|
|
VDSStorageIdTypeVendorSpecific = 0,
|
|
|
|
/// <summary>The storage identifier is the same as the vendor identifier.</summary>
|
|
VDSStorageIdTypeVendorId,
|
|
|
|
/// <summary>The storage identifier type follows the IEEE 64-bit Extended Unique Identifier (EUI-64) standard.</summary>
|
|
VDSStorageIdTypeEUI64,
|
|
|
|
/// <summary>
|
|
/// <para>The storage identifier type follows the Fibre Channel Physical and Signaling Interface (FC-PH) naming</para>
|
|
/// <para>convention.</para>
|
|
/// </summary>
|
|
VDSStorageIdTypeFCPHName,
|
|
|
|
/// <summary>
|
|
/// <para>VDS 1.1:</para>
|
|
/// <para>The storage identifier type is dependent on the port.</para>
|
|
/// </summary>
|
|
VDSStorageIdTypePortRelative,
|
|
|
|
/// <summary/>
|
|
VDSStorageIdTypeTargetPortGroup,
|
|
|
|
/// <summary/>
|
|
VDSStorageIdTypeLogicalUnitGroup,
|
|
|
|
/// <summary/>
|
|
VDSStorageIdTypeMD5LogicalUnitIdentifier,
|
|
|
|
/// <summary/>
|
|
VDSStorageIdTypeScsiNameString,
|
|
}
|
|
|
|
/// <summary>
|
|
/// <para>
|
|
/// [Beginning with Windows 8 and Windows Server 2012, the Virtual Disk Service COM interface is superseded by the Windows Storage
|
|
/// Management API.]
|
|
/// </para>
|
|
/// <para>Defines the address data of a physical interconnect.</para>
|
|
/// </summary>
|
|
/// <remarks>
|
|
/// The VDS_LUN_INFORMATION structure includes this structure as a member to specify an interconnect by which a LUN can be accessed.
|
|
/// </remarks>
|
|
// https://docs.microsoft.com/en-us/windows/win32/api/vdslun/ns-vdslun-vds_interconnect typedef struct _VDS_INTERCONNECT {
|
|
// VDS_INTERCONNECT_ADDRESS_TYPE m_addressType; ULONG m_cbPort; BYTE *m_pbPort; ULONG m_cbAddress; BYTE *m_pbAddress; } VDS_INTERCONNECT;
|
|
[PInvokeData("vdslun.h", MSDNShortId = "NS:vdslun._VDS_INTERCONNECT")]
|
|
[StructLayout(LayoutKind.Sequential)]
|
|
public struct VDS_INTERCONNECT
|
|
{
|
|
/// <summary>The interconnect address type enumerated by VDS_INTERCONNECT_ADDRESS_TYPE.</summary>
|
|
public VDS_INTERCONNECT_ADDRESS_TYPE m_addressType;
|
|
|
|
/// <summary>The size of the interconnect address data for the LUN port ( <c>m_pbPort</c>), in bytes.</summary>
|
|
public uint m_cbPort;
|
|
|
|
/// <summary>Pointer to the interconnect address data for the LUN port.</summary>
|
|
public IntPtr m_pbPort;
|
|
|
|
/// <summary>The size of the interconnect address data for the LUN ( <c>m_pbAddress</c>), in bytes.</summary>
|
|
public uint m_cbAddress;
|
|
|
|
/// <summary>Pointer to the interconnect address data for the LUN.</summary>
|
|
public IntPtr m_pbAddress;
|
|
}
|
|
|
|
/// <summary>
|
|
/// <para>
|
|
/// [Beginning with Windows 8 and Windows Server 2012, the Virtual Disk Service COM interface is superseded by the Windows Storage
|
|
/// Management API.]
|
|
/// </para>
|
|
/// <para>Defines information about a LUN or disk. Applications can use this structure to uniquely identify a LUN at all times.</para>
|
|
/// </summary>
|
|
/// <remarks>
|
|
/// <para>
|
|
/// The <c>VDS_LUN_INFORMATION</c> structure includes fields from the SCSI Inquiry Data and Vital Product Data pages 0x80 and 0x83. The
|
|
/// <c>GetIdentificationData</c> method on both the IVdsLun and IVdsDisk interfaces return this structure. It is also passed as an
|
|
/// argument in the IVdsHwProviderPrivate::QueryIfCreatedLun method to determine whether a given provider owns a specified LUN.
|
|
/// </para>
|
|
/// <para>
|
|
/// To get the LUN object, use the IVdsService::GetObject method. You can then use the IVdsLun::GetProperties method to get the LUN properties.
|
|
/// </para>
|
|
/// </remarks>
|
|
// https://docs.microsoft.com/en-us/windows/win32/api/vdslun/ns-vdslun-vds_lun_information typedef struct _VDS_LUN_INFORMATION { ULONG
|
|
// m_version; BYTE m_DeviceType; BYTE m_DeviceTypeModifier; BOOL m_bCommandQueueing; VDS_STORAGE_BUS_TYPE m_BusType; char *m_szVendorId;
|
|
// char *m_szProductId; char *m_szProductRevision; char *m_szSerialNumber; GUID m_diskSignature; VDS_STORAGE_DEVICE_ID_DESCRIPTOR
|
|
// m_deviceIdDescriptor; ULONG m_cInterconnects; VDS_INTERCONNECT *m_rgInterconnects; } VDS_LUN_INFORMATION;
|
|
[PInvokeData("vdslun.h", MSDNShortId = "NS:vdslun._VDS_LUN_INFORMATION")]
|
|
[StructLayout(LayoutKind.Sequential)]
|
|
public struct VDS_LUN_INFORMATION
|
|
{
|
|
/// <summary></summary>
|
|
public const uint VER_VDS_LUN_INFORMATION = 1;
|
|
|
|
/// <summary>The version of this structure. The current value is the constant <c>VER_VDS_LUN_INFORMATION</c>.</summary>
|
|
public uint m_version;
|
|
|
|
/// <summary>The SCSI-2 device type of the LUN.</summary>
|
|
public byte m_DeviceType;
|
|
|
|
/// <summary>The SCSI-2 device type modifier of the LUN. For LUNs that have no device type modifier, the value is zero.</summary>
|
|
public byte m_DeviceTypeModifier;
|
|
|
|
/// <summary>
|
|
/// If <c>TRUE</c>, the LUN supports multiple outstanding commands; otherwise, <c>FALSE</c>. The synchronization of the queue is the
|
|
/// responsibility of the port driver.
|
|
/// </summary>
|
|
[MarshalAs(UnmanagedType.Bool)]
|
|
public bool m_bCommandQueueing;
|
|
|
|
/// <summary>The bus type of the LUN enumerated by VDS_STORAGE_BUS_TYPE.</summary>
|
|
public VDS_STORAGE_BUS_TYPE m_BusType;
|
|
|
|
/// <summary>
|
|
/// Pointer to the LUN vendor identifier; a zero-terminated, human-readable string. For devices that have no vendor identifier, the
|
|
/// value is zero.
|
|
/// </summary>
|
|
[MarshalAs(UnmanagedType.LPStr)]
|
|
public string m_szVendorId;
|
|
|
|
/// <summary>
|
|
/// Pointer to the LUN product identifier, typically a model number; a zero-terminated, human-readable string. For devices that have
|
|
/// no product identifier, the value is zero.
|
|
/// </summary>
|
|
[MarshalAs(UnmanagedType.LPStr)]
|
|
public string m_szProductId;
|
|
|
|
/// <summary>
|
|
/// Pointer to the LUN product revision; a zero-terminated, human-readable string. For devices that have no product revision, the
|
|
/// value is zero.
|
|
/// </summary>
|
|
[MarshalAs(UnmanagedType.LPStr)]
|
|
public string m_szProductRevision;
|
|
|
|
/// <summary>
|
|
/// Pointer to the LUN serial number; a zero-terminated, human-readable string. For devices that have no serial number, the value is zero.
|
|
/// </summary>
|
|
[MarshalAs(UnmanagedType.LPStr)]
|
|
public string m_szSerialNumber;
|
|
|
|
/// <summary>
|
|
/// The signature of the LUN. For disks that use the Master Boot Record (MBR) partitioning structure, the first 32 bits of the GUID
|
|
/// comprise the disk signature, and the remaining bits are zeros. For disks that use the GUID Partition Table (GPT) partitioning
|
|
/// structure, the GUID consists of the GPT disk identifier. If this value is zero, the disk is uninitialized or the hardware
|
|
/// provider was unable to retrieve the signature.
|
|
/// </summary>
|
|
public Guid m_diskSignature;
|
|
|
|
/// <summary>
|
|
/// Array containing the LUN descriptor in various formats, such as "VDSStorageIdTypeFCPHName" and "VDSStorageIdTypeVendorSpecific".
|
|
/// Providers can use "VDSStorageIdTypeVendorSpecific" to store an arbitrary byte string of the vendor's choosing to uniquely
|
|
/// identify the LUN. See the VDS_STORAGE_DEVICE_ID_DESCRIPTOR structure and the VDS_STORAGE_IDENTIFIER structure.
|
|
/// </summary>
|
|
public VDS_STORAGE_DEVICE_ID_DESCRIPTOR m_deviceIdDescriptor;
|
|
|
|
/// <summary>The number of interconnect ports specified in <c>m_rgInterconnects</c>.</summary>
|
|
public uint m_cInterconnects;
|
|
|
|
/// <summary>
|
|
/// Pointer to an array of the interconnect ports by which the LUN can be accessed. See the <see cref="VDS_INTERCONNECT"/> structure.
|
|
/// </summary>
|
|
public IntPtr m_rgInterconnects;
|
|
}
|
|
|
|
/// <summary>
|
|
/// <para>
|
|
/// [Beginning with Windows 8 and Windows Server 2012, the Virtual Disk Service COM interface is superseded by the Windows Storage
|
|
/// Management API.]
|
|
/// </para>
|
|
/// <para>Defines one or more storage identifiers for a storage device (typically an instance, as opposed to a class, of device).</para>
|
|
/// </summary>
|
|
/// <remarks>
|
|
/// Storage devices can have multiple identifiers, and each of these identifiers can have a different code set and type. The
|
|
/// VDS_LUN_INFORMATION structure includes this structure as a member to specify the storage device identifiers of a LUN.
|
|
/// </remarks>
|
|
// https://docs.microsoft.com/en-us/windows/win32/api/vdslun/ns-vdslun-vds_storage_device_id_descriptor typedef struct
|
|
// _VDS_STORAGE_DEVICE_ID_DESCRIPTOR { ULONG m_version; ULONG m_cIdentifiers; VDS_STORAGE_IDENTIFIER *m_rgIdentifiers; } VDS_STORAGE_DEVICE_ID_DESCRIPTOR;
|
|
[PInvokeData("vdslun.h", MSDNShortId = "NS:vdslun._VDS_STORAGE_DEVICE_ID_DESCRIPTOR")]
|
|
[StructLayout(LayoutKind.Sequential)]
|
|
public struct VDS_STORAGE_DEVICE_ID_DESCRIPTOR
|
|
{
|
|
/// <summary>The version of this structure.</summary>
|
|
public uint m_version;
|
|
|
|
/// <summary>The number of identifiers specified in <c>m_rgIdentifiers</c>.</summary>
|
|
public uint m_cIdentifiers;
|
|
|
|
/// <summary>Pointer to <see cref="VDS_STORAGE_IDENTIFIER"/> structure.</summary>
|
|
public IntPtr m_rgIdentifiers;
|
|
}
|
|
|
|
/// <summary>
|
|
/// <para>
|
|
/// [Beginning with Windows 8 and Windows Server 2012, the Virtual Disk Service COM interface is superseded by the Windows Storage
|
|
/// Management API.]
|
|
/// </para>
|
|
/// <para>Defines a storage device using a particular code set and type.</para>
|
|
/// </summary>
|
|
/// <remarks>
|
|
/// The VDS_STORAGE_DEVICE_ID_DESCRIPTOR structure includes this structure as a member to specify a particular storage device identifier
|
|
/// for a LUN.
|
|
/// </remarks>
|
|
// https://docs.microsoft.com/en-us/windows/win32/api/vdslun/ns-vdslun-vds_storage_identifier typedef struct _VDS_STORAGE_IDENTIFIER {
|
|
// VDS_STORAGE_IDENTIFIER_CODE_SET m_CodeSet; VDS_STORAGE_IDENTIFIER_TYPE m_Type; ULONG m_cbIdentifier; BYTE *m_rgbIdentifier; } VDS_STORAGE_IDENTIFIER;
|
|
[PInvokeData("vdslun.h", MSDNShortId = "NS:vdslun._VDS_STORAGE_IDENTIFIER")]
|
|
[StructLayout(LayoutKind.Sequential)]
|
|
public struct VDS_STORAGE_IDENTIFIER
|
|
{
|
|
/// <summary>The encoding type of <c>m_rgbIdentifier</c> enumerated by VDS_STORAGE_IDENTIFIER_CODE_SET.</summary>
|
|
public VDS_STORAGE_IDENTIFIER_CODE_SET m_CodeSet;
|
|
|
|
/// <summary>The type of <c>m_rgbIdentifier</c> enumerated by VDS_STORAGE_IDENTIFIER_TYPE.</summary>
|
|
public VDS_STORAGE_IDENTIFIER_TYPE m_Type;
|
|
|
|
/// <summary>The size of the <c>m_rgbIdentifier</c> array, in bytes.</summary>
|
|
public uint m_cbIdentifier;
|
|
|
|
/// <summary>Pointer to the identifier data.</summary>
|
|
public IntPtr m_rgbIdentifier;
|
|
}
|
|
} |